Stephen P. Wales Home  

    The Old Brewery Works, Lower Ellacombe Church Rd.  Torquay.  U.K. post code:TQ1 1JH  Tel: 01803 215390/295430 Fax: 01803 212819

 

 

‘Smith’ type Coin Meters

 

GENERAL

 

·         Handle and install carefully - it is a sensitive instrument.  Wire as diagram: -

 

 

                                          Check that the rotation is left to right. If not-rewire correctly.

 

·         A badly handled or transit damaged Meter could develop a fault during the first few weeks. The landlord should check more closely during this period.

 

·         Setting:- Rates vary around the country. Check with your local electricity board as to what the setting should be.

 

·         To convert from 'Pence per unit' to 'Units per coin' use the following formula.

         ‘UNITS-PER-COIN’   =    100  ¸  ‘PENCE-PER-UNIT’

 

·         Where Meters cannot be set exactly. The nearest setting should be used.

 

RECOMMENDATIONS

 

1.        Check the meters, meter readings and the seals regularly.

2.        Bent or damaged coins will sometimes need to be removed by the Landlord.

3.        Make a record of the readings as below: -

DATE.

UNITS.

SET AT.

COINS   INSERTED.

MONEY

COLLECTED

example

200

8 pence/unit

(12 .4 units per coin)

16

£16.00

 

360

29

£13.00

SETTING YOUR METER: SMITH METER

1.        Remove cashbox,

2.        Undo hexagonal nut which releases the retaining ring (see drawing).

3.        Note  the 'Set-at' position on the retaining ring. (For Pound-Coin Meters you are only concerned with the 'B-Rate' Scale).

4.        With the coin slots open, withdraw the 'coin-action'.

5.         Then replace at the required setting.